Setup
Running time after last detection
After the hand has left the detection range of the sensor, the water can continue to run for a certain time. This time is called the running time after last detection and it can be set individually. If there are high demands on hygiene, as in hospitals or doctor's offices, a long run-on time is advantageous. For example to rinse soap residue from the sink.\n
Adjusting the running time after last detection
- First connect the remote control with the tap.
- Select the menu item "Configuration".
- Use the arrow keys to set the slider between 0 and 19 sec at "running time after last detection".
- Scroll all the way down with the arrow keys to transfer the new setting data to the tap by pressing "Send”.
- The check mark in the upper right corner of the remote control display indicates that the transfer was successful.
The factory setting for the running time is 1 second. \nHowever, if “saving water” is an important goal, the running time can even be set to 0 seconds.